This appears to have been broken in ac3e8a4a59,
which removed the `jobsetevals` column from the Projects schema, but didn't
update the Controller accordingly.
Fixes the test added in the previous commit.
To further align with the API, we return custom JSON in order to display a
`visible` field rather than `hidden` -- a `PUT` request expects `visible`, while
a `GET` request returns `hidden`.
This also allows us to rename the `jobsetinputs` field to `inputs` for the same
reason: `PUT` expects `inputs`, while `GET` returns `jobsetinputs`.
`PUT /jobsets/{project-id}/{jobset-id}` expects a JSON object `inputs` which
maps a name to a name, a type, a value, and a boolean that enables emailing
responsible parties. However, `GET /jobsets/{project-id}/{jobset-id}` responds
with an object that doesn't contain a value, but does contain a jobsetinputalts
(which is old and should be unused).
This commit aligns the two by removing the old and unused `jobsetinputalts` from
the response and replaces it with `value`.
* made all columns available via the API (except for forceeval)
* renamed flakeref to flake to unify the API with the database schema
* renamed inputs to jobsetinputs to unify the API with the database schema
The checkbox is only enabled if `email_notification = 1` is set in
`hydra.conf`. However, when creating jobset (in contrast to the edit
form), the checkbox is always disabled because the `emailNotification`
parameter in Catalyst's stash was missing.
Passwords that are sha1 will be transparently upgraded to argon2,
and future comparisons will use Argon2
Co-authored-by: Graham Christensen <graham@grahamc.com>
The default password comparison logic does not use
constant time validation. Switching to constant time
offers a meager improvement by removing a timing
oracle.
A prepatory step in moving to Argon2id password storage, since we'll need this change anyway after
for validating existing passwords.
Co-authored-by: Graham Christensen <graham@grahamc.com>
Some time in the last decade the plugin switched to preferring
a flatter namespace for realm config.
Co-authored-by: Graham Christensen <graham@grahamc.com>
In Nix the protocol was slightly altered[1] to also contain more
information about realisations. This however wasn't read from the pipe
that was used to read from the store.
After the `cmdBuildDerivation` command which caused this issue, Hydra
will issue a `cmdQueryPathInfos` that tries to read from the remote
store as well. However, there's still left over to read from the
previous command and thus Nix fails to properly allocate the expected
string.
[1] See rev a2b69660a9b326b95d48bd222993c5225bbd5b5f
Fixes#898