Currently I'm using a (not very well) downscaled version of the NixOS
logo, so we want to replace it by a proper image ASAP.
Other than that, the idea is to have something like this in
hydra-build-products:
file channel $out/channel.tar.bz2
Right now of course, it's only displayed at the corresponding builds, so
we might want to have aggregates on all channels for a project, jobset
or maybe even single jobs?
Signed-off-by: aszlig <aszlig@redmoonstudios.org>
They will show up in machineTypes as (e.g.) x86_64-linux:local instead
of x86_64-linux. This is to prevent the Hydra provisioner from
creating machines for steps that are supposed to be executed locally.
It's easier for the Hydra provisioner to put host public keys in the
machines file than to separately manage the known_hosts file
(especially when the provisioner runs on a different machine).
This is necessary because the required system type can become
available later (e.g. by being provisioned by the
auto-scaler). However, in the future, we may want to fail steps if
they have been unsupported for more than a certain amount of time.
For example, steps that require the "kvm" feature may require a
different kind of machine to be provisioned. This can also be used to
require performance-sensitive tests to run on a particular kind of
machine, e.g., by setting requiredSystemFeatures to something like
"ec2-i2.8xlarge".
"hydra-queue-runner --status" now prints how many runnable and running
build steps exist for each machine type. This allows additional
machines to be provisioned based on the Hydra load.
If there is no input named 'inputs', hydra-eval-jobs now passes in a set
of lists, where each attribute corresponds to an input defined in the
jobset specification and each list element is a different input alt, as
an argument named 'inputs'.
Among other things, this allows for generic hydra expressions to be
shared amongst projects with similar structures but different sets of
specific inputs.
Builds can now emit metrics that Hydra will store in its database and
render as time series via flot charts. Typical applications are to
keep track of performance indicators, coverage percentages, artifact
sizes, and so on.
For example, a coverage build can emit the coverage percentage as
follows:
echo "lineCoverage $pct %" > $out/nix-support/hydra-metrics
Graphs of all metrics for a job can be seen at
http://.../job/<project>/<jobset>/<job>#tabs-charts
Specific metrics are also visible at
http://.../job/<project>/<jobset>/<job>/metric/<metric>
The latter URL also allows getting the data in JSON format (e.g. via
"curl -H 'Accept: application/json'").
If Hydra isn't hosted on https://example.com/ but something like
https://example.com/hydra/, the URL for /api/scmdiff would have ended up
on /api/scmdiff rather than /hydra/api/scmdiff.
This is because we didn't use the URI resolver from the controller,
hence we're using it now to build up the whole URL including the query
string.
Signed-off-by: aszlig <aszlig@redmoonstudios.org>
Without an index on (machine, stoptime desc), this requires a
sequential scan. And adding a whole index for this seems
overkill. (Possibly the queue runner could maintain this info more
efficiently.)
This prevents a race where multiple threads see that machine X is
missing path P, and start sending it concurrently. Nix handles this
correctly, but it's still wasteful (especially for the case where P ==
GHC).
A more refined scheme would be to have per machine, per path locks.
Derivations with "preferLocalBuild = true" can now be executed on
specific machines (typically localhost) by setting the mandary system
features field to include "local". For example:
localhost x86_64-linux,i686-linux - 10 100 - local
says that "localhost" can *only* do builds with "preferLocalBuild =
true". The speed factor of 100 will make the machine almost always win
over other machines.
Otherwise we never recover from reset daemon connections, e.g.
hydra-queue-runner[16106]: while loading build 599369: cannot start daemon worker: reading from file: Connection reset by peer
hydra-queue-runner[16106]: while loading build 599236: writing to file: Broken pipe
...
The error is now handled queueMonitor(), causing the next call to
queueMonitorLoop() to create a new connection.
This is currently done by a separate program that periodically
calls "hydra-queue-runner --status". Eventually, I'll do this
in the queue runner directly.
Fixes#220.