The job has been failing since https://hydra.nixos.org/eval/1461286
with the following error:
hydra-eval-jobs.cc:278:17: error: 'evalSettings' was not declared in this scope
evalSettings.restrictEval = true;
^~~~~~~~~~~~
This is likely due to a typo in 0882519 where that line and the
corresponding comment were moved, and `settings` was changed in that
one place to `evalSettings`.
I reproduced the error by running `nix-build release.nix -A
build.x86_64-linux` on my machine, and this small change fixes it.
You can now set 'evaluator_max_heap_size' to make hydra-eval-jobs
restart itself if the Boehm heap exceeds the specified size.
For example, with 'evaluator_max_heap_size = 256000000',
$ hydra-eval-jobs '<nixpkgs/pkgs/top-level/release.nix>' -I nixpkgs=channel:nixos-17.09
has a max RSS of .56 GiB rather than 4.7 GiB.
Unfortunately it doesn't help much for the NixOS jobsets because of
the "tested" job which requires a huge amount of memory all by itself.
This cannot be done in the hydra-evaluator systemd unit, since then
every other Nix process (e.g. hydra-evaluator and nix-prefetch-*) will
also allocate the specified heap size, probably leading to OOM.
Also, remove support in hydra-eval-jobs for multiple jobset input
alternatives. The web interface hasn't supported this in a long
time. Thus we can use the regular "--arg" handler.
This is to properly separate channels from regular jobs and also make
sure that we can always iterate on them, no matter whether the build has
failed. The reason why we were not able to do this until now was because
we were iterating on the build products, and whenever some constituent
of a channel job has failed, we didn't get a build output.
So whenever there is a meta.isHydraChannel, we can now properly
distinguish it from the other jobs.
I still don't have any clue, why "make -C src/sql update-dbix" without
*any* modifications tries to create additional schema definitions. But
I've checked the md5sums of the existing schema definitions and they
don't seem to match, so it seems that they already have been tampered
with.
Signed-off-by: aszlig <aszlig@redmoonstudios.org>
If there is no input named 'inputs', hydra-eval-jobs now passes in a set
of lists, where each attribute corresponds to an input defined in the
jobset specification and each list element is a different input alt, as
an argument named 'inputs'.
Among other things, this allows for generic hydra expressions to be
shared amongst projects with similar structures but different sets of
specific inputs.