In Nix the protocol was slightly altered[1] to also contain more
information about realisations. This however wasn't read from the pipe
that was used to read from the store.
After the `cmdBuildDerivation` command which caused this issue, Hydra
will issue a `cmdQueryPathInfos` that tries to read from the remote
store as well. However, there's still left over to read from the
previous command and thus Nix fails to properly allocate the expected
string.
[1] See rev a2b69660a9b326b95d48bd222993c5225bbd5b5f
Fixes#898
Previously, the build ID would never flow through channels which
exited.
This patch tracks the buildOne state as part of State and exits avoids
waiting forever for new work.
The code around buildOnly is a bit rough, making this a bit weird to
implement but since it is only used for testing the value of improving
it on its own is a bit questionable.
The queue runner used to special-case `localhost` as a remote builder:
Rather than using the normal remote-build (using the
`cmdBuildDerivation` command), it was using the (generally less
efficient, except when running against localhost) `cmdBuildPaths`
command because the latter didn't require a privileged Nix user (so made
testing easier − allowing to run hydra in a container in particular).
However:
1. this means that the build loop can follow two discint code paths depending
on the setup, the irony being that the most commonly used one in production
(the “non-localhost” case) isn't the one used in the testsuite (because all
the tests run against a local store);
2. It turns out that the “localhost” version is buggy in relatively obvious
ways − in particular a failure in a fixed-output derivation or a hash
mismatch isn't reported properly;
3. If the “run in a container” use-case is indeed that important, it can be
(partially) restored using a chroot store (which wouldn't behave excactly
the same way of course, but would be more than good-enough for testing)
This would start happening if the network connection between the Hydra
server and the remote build server breaks after sucessfully importing
at least one output of a derivation, but before having finished
importing all outputs.
Fixes#816.
Recently a few internal APIs have changed[1]. The `outputPaths` function
has been removed and a lot of data structures are modeled with
`std::optional` which broke compilation.
This patch updates the code in `hydra-queue-runner` accordingly to make
sure that Hydra compiles again.
[1] https://github.com/NixOS/nix/pull/3883
If we don't see machine that supports a build step for
'max_unsupported_time' seconds, the step is aborted. The default is 0,
which is appropriate for Hydra installations that don't provision
missing machines dynamically.
(cherry picked from commit f5cdbfe21d)
Building on macOS with the latest nixpkgs master and NixOS/nixpkgs#77147
fails. It seems some `std::experimental` (optional) for instance are
not available as `experimental`, but are in `std`. Also `toJSON` is
missing for `atomic< unsigned long long >`.
In a NixOS container, cmdBuildDerivation doesn't work because we're
not privileged. But we also don't need it because the store already
has the derivation.
Also, don't copy from/to the store since this gives errors about