Fix#6209
When trying to run `nix log <installable>`, try first to resolve the derivation pointed to
by `<installable>` as it is the resolved one that holds the build log.
This has a couple of shortcomings:
1. It’s expensive as it requires re-reading the derivation
2. It’s brittle because if the derivation doesn’t exist anymore or can’t
be resolved (which is the case if any one of its build inputs is missing),
then we can’t access the log anymore
However, I don’t think we can do better (at least not right now).
The alternatives I see are:
1. Copy the build log for the un-resolved derivation. But that means a
lot of duplication
2. Store the results of the resolving in the db. Which might be the best
long-term solution, but leads to a whole new class of potential
issues.